SC 1.1 GMN – Gas regulación modulante neumática

SC. 1.1 GMN

Power Kw/h Min 18
Max 120
kcal/h Min 15.480
Max  103.200
Tensión Suministro 1N – 50 Hz 230V
Motor kW 0,15
Diam. válvula 300 mbar 3/4″
Category:

More information

Modulating burners with electronic regulation regulation represent an evolution of the traditional mechanical type adjustment system towards a digital type system.
The servomotors of each of the air, gas and liquid fuel flow adjustment devices respond to orders from a microprocessor in which the parameter curves defined for each of these elements have been recorded.

  1. Duoblock burners with high temperature steel housing and combustion head.
  2.  The following fuels may be used: Natural gas, PCI 6.99 … 11.39 kWh/m3; LPG, PCI 25.89 kWh/m3; Biogas
  3. It is suitable for steam, hot water boiler, furnaces, dryers, thermal oil generators, etc.
  4. Each burner can be customized to the needs of the installation.
  5. Digital programming is done on the screen or using a computer, and following the simple instructions.
  6. The additional advantage offered by the system lies in the precise knowledge of all the commands and all the states of the system as a whole.
  7. In addition, the microprocessor system also performs the following functions:
  8. Control and monitoring of the burner start-up and operation phases, with the possibility of configuring the set modes and times;
  9. La facilidad del diseño y el uso de aire de combustión precalentado al tiempo que permite el ahorro de energía al aumentar la eficiencia del economizador de combustión utilizado por el sistema.
  10.  Flame control, with different monitoring devices, for intermittent or continuous operation (more than 24 hours);
  11. Integrated gas valve check system checks for leaks at each burner cycle for added safety
  12. Up to 15 programmable points for each air-fuel ratio curve
  13. Access levels are protected by specific passwords corresponding to the different types of users (viewing by customer, programming by technician, etc.).
  14. The system can be completed by integrating it with a system of automatic adjustment of excess air by oxygen sensor with action on the position of the air damper.
  15. Up to 15 programmable points for each air-fuel ratio curve
  16. Access levels are protected by specific passwords corresponding to the different types of users (viewing by customer, programming by technician, etc.).
  17. The system can be completed by integrating it with a system of automatic adjustment of excess air by oxygen sensor with action on the position of the air damper.
  18. Finally the fan speed adjustment system with variable speed drive to ensure maximum energy savings, both fuel and electrical energy.
  19. Standard protection of mechanical parts IP 54.
  20. IP 65 protection on request.
  21. The flame can be adjusted according to the combustion chamber.
  22. Compliance with the following directives:
    89/336 (2004/108)
    EEC 73/23/
    EEC 98/37/
    EEC EN 676
en_USEnglish